ELECTRICAL PANEL · MALAGA — ESTEPONA
Electrical panel replacement in villas and homes on the Costa del Sol
The consumer unit protects the entire electrical installation of the home and the people who live in it. Sostera, an electrical installation company authorised by the Junta de Andalucía (RII 01-B-D00-29038379), replaces, upgrades and extends consumer units in line with the Spanish Low Voltage Electrical Regulations (REBT), in villas and homes from Málaga to Estepona: Málaga, Torremolinos, Benalmádena, Fuengirola, Mijas, Marbella, San Pedro Alcántara, Benahavís and Estepona.
What is an electrical panel and what does it contain?
The main distribution board is the point from which electricity is distributed to all circuits in the home. Its components are regulated by ITC-BT-17 of the REBT (Spanish Low Voltage Electrotechnical Regulations) and, in residential buildings, by ITC-BT-25. A compliant distribution board includes at least the following:
Automatic main switch (IGA), which protects the entire installation against overloads and short circuits.
High sensitivity differential switches (30 mA), which cut off the current in the event of a ground fault and protect people from indirect contact.
Miniature circuit breakers (MCBs), one per circuit, sized according to the cable section and the use of the circuit.
Protection against overvoltages, transient and permanent, according to ITC-BT-23 and the characteristics of the installation.
When should the electrical panel be replaced?
These are the situations in which we recommend replacing or adapting the frame:
The panel still has fuses (the old "leads") or does not have a differential switch.
The circuit breakers or thermal-magnetic switches frequently trip for no apparent reason.
There are signs of overheating: a burning smell, discoloration, or mechanisms that get hot.
The contracted power will be increased or the power will be changed from single-phase to three-phase.
New circuits are added: electric vehicle charging point, swimming pool, aerothermal heating, air conditioning or home automation.
The house is renovated or an old house is purchased whose installation is not documented.
Electrical panels in villas: main panel and sub-panels
In a villa, a single electrical panel is rarely sufficient. We designed a main panel and sub-panels for different zones (upper floor, pool, garden, garage), with distributed residual current protection (RCD) so that a fault in the garden doesn't leave the interior without power. We applied selectivity criteria between protection devices and, for sensitive equipment such as air conditioning, home automation, or computer equipment, we used highly immune RCDs that prevent nuisance tripping.
Each panel is delivered fully organized, with all circuits labeled, a single-line diagram, and space reserved for future expansion. When the villa incorporates KNX home automation, the actuators are integrated into the panel itself, mounted on a DIN rail.
Circuits and degree of electrification according to the REBT
The ITC-BT-25 standard establishes two levels of electrification for homes: basic, with a minimum provision of 5,750 W at 230 V, and advanced, with a minimum of 9,200 W, mandatory when there is air conditioning, electric heating, home automation, or large areas, as is the case in most villas. Each use has its own independently protected circuit: lighting, general-purpose outlets, kitchen and oven, washing machine and water heater, bathrooms and kitchen, and in advanced electrification, additional circuits for heating, air conditioning, dryer, or automation.
Special circuits follow their own instructions: ITC-BT-31 for swimming pools and ITC-BT-52 for electric vehicle charging, which requires a dedicated circuit and protection.
How we changed your electrical panel
1. Review. We check the existing panel, the cable sections, the grounding and the expected power.
2. Proposal. We will send you a detailed offer within 24 hours, with the composition of the new frame.
3. Replacement. We install the new panel with the minimum supply interruption time, giving advance notice.
4. Testing and documentation. We measure the resistance of the grounding system, verify the tripping of the differential switches, and provide you with the electrical panel diagram and, where applicable, the updated electrical certificate.
Frequently asked questions about the electrical panel
Why does the circuit breaker trip?
This is usually caused by a ground fault in an appliance or circuit, by moisture, or by deteriorated insulation. It can also be due to an old or incorrectly sized residual current device (RCD). We locate the affected circuit before replacing anything.
What is a super-immunized differential?
It is a 30 mA differential designed not to trip due to disturbances generated by electronic equipment, such as inverters, chargers or air conditioners, while still protecting people against real leaks.
Do I need a new electrical certificate when I change the panel?
If the replacement involves an increase in power or a modification of the installation, then yes. For a replacement without changes in power, it depends on the scope of the work: we will specify this in the quote.
Can I install an electric vehicle charger with my existing electrical panel?
It depends on the available power and the space in the electrical panel. Charging requires a dedicated circuit and protection according to ITC-BT-52; we will review your installation and propose the appropriate solution.
How much does it cost to replace an electrical panel?
It depends on the number of circuits, sub-panels, and required protection devices. We will send you a fixed-price quote within 24 hours of inspecting the installation.